Process ground to peripheral cmnds

Process ground to peripheral cmnds

TITLE
Process Cam/FP Ground Messages
PURPOSE
To send the camera or FP messages directly from the ground.
DESCRIPTION
This observation program is scheduled when a command comes from the ground with the destination address of one of the five peripherals. The messages are sent to the peripheral exactly as it was received from the ground. The time that the command is to be executed can be immediate (next in the queue) or in the future.
LP NUMBER
11
INPUT PARAMETERS
		   Parameter	Description
			#
		       1-20	The IDS for the camera or Fabry-Perot is 
				followed exactly.
MODULE NAME
OP_PROCESS_CAM_FP_GRND_MSGS.C