TITLE 		Take Calibration Lamp Images

PURPOSE 	To take calibration lamp images from C1-EIT

DESCRIPTION 	This observation program is used to take calibration lamp
		images, possibly using shutters, from C1, C2, C3 and
		EIT.  C1 and C2 have lamps that illuminate the front door,
		so the door must be closed when these are scheduled to be
		run.  C2 and C3 have lamps that illuminate the back
		of the shutter and therefore don't require the door to be
		closed, and of course the shutter won't move.  The EIT has
		a lamp that illuminates the CCD directly.

		The operator schedules this LP with the parameters
		which include which of the 4 telescopes are to be used,
		as well as which FW position, PW position, and image
		processing table number to process the image data. The
		calibration parameter table will be used.

LP Number 	17

INPUT PARAMETERS
		   Parameter	Description
			#

			1	Telescope (0-3)
			2	Parameter table number
					1 = primary
					2 = alternate
					3 = calibration
			3	Filter wheel position (0-4)
			4	Polarizer wheel position (0-4)
			5	Image processing table
			6	Lamp Number
					2 = Door
					3 = Shutter

MODULE NAME 	OP_TAKE_CAL_LAMP.C